In astable mode the 555 charges a capacitor through R1 + R2 and discharges it through R2 alone, so the output is high longer than it is low. Enter the two resistors and the capacitor.

555 Timer Calculator (Astable)

Frequency = 1.44 / ((R1 + 2 x R2) x C). The duty cycle is always above 50% in this classic circuit; other topologies go below.