Power Factor Explained: The Froth on the Beer

When current and voltage fall out of step

In a resistive load, current and voltage rise and fall together and every watt the supply delivers does work. In motors, transformers and other inductive loads, the current lags behind the voltage; with capacitive loads it leads. Part of the current then sloshes back and forth, magnetising cores and charging capacitances, delivering no net energy but occupying cables, transformers and generators all the same. Power factor is the ratio of real power, in watts, to apparent power, in volt-amperes: one when the two waveforms march together, falling towards zero as they drift apart.

Why anyone pays for an angle

The sloshing current heats cables and loads transformers exactly like useful current, so a factory drawing 100 amps at a power factor of 0.7 receives only 70 percent of the work those 100 amps could have delivered, while the utility's equipment carries the full burden. Large customers are therefore billed penalties for poor power factor and fit correction capacitors that supply the magnetising current locally, cancelling the lag at the boundary. The famous beer analogy survives because it is accurate: the liquid is the watts you wanted, the foam is the reactive part, and the glass, sized by apparent power, must hold both.

Power factor at home and in electronics

Domestic users are billed for real energy only, so home power factor is a curiosity rather than a cost, though it still loads the house wiring. A second, modern kind of poor power factor comes from distortion rather than phase: switch-mode supplies gulp current in short peaks at the voltage crest, and the resulting harmonic currents behave like a bad power factor even in a resistive-looking load. Regulations now require correction in larger supplies, which is why quality power supplies advertise active PFC. The PSU load figures on this site assume the real-power side; add the angle, and you understand what the supply upstream is really carrying. Correction has a satisfying concreteness. The capacitor fitted across a motor or a fluorescent fitting is sized in kilovars, reactive kilovolt-amperes, to supply locally what the load was importing from the network, and the supply current falls measurably the moment it is connected, which you can watch on a clamp meter. Too much correction is its own fault, pushing the factor leading and voltages upward, so industrial systems switch capacitor steps in and out as the load changes. At the scale of a single bench, the lesson is diagnostic: when a transformer or generator seems undersized for the watts it feeds, measure the volt-amperes and the angle between them before blaming the iron. The missing capacity is usually hiding in the phase.

Try the numbers yourself

The free calculator that goes with this guide:

Open the PSU load calculator