A printed circuit board trace is a flat copper wire glued to a board, and like any wire it has resistance and warms under current. Unlike a wire in free air, it is sandwiched against or inside a fibreglass board that insulates it thermally, so its temperature for a given current is a design decision, not an afterthought. Designers budget a temperature rise, commonly 10 to 20 degrees above ambient, and choose the trace width to stay inside it. Exceed the budget badly and the board discolours, the copper can delaminate, and in the extreme the trace fuses like the element it has accidentally become.
The long-standing generic formula, from the IPC-2221 standard, relates current to the trace cross-sectional area, with constants that differ for external layers, which shed heat to the air, and internal layers, which are buried and need roughly twice the copper for the same rise. Copper weight enters through thickness: 1 ounce copper is about 35 micrometres, 1.378 mils, thick. Feed in current, allowed rise, copper weight and layer, and the trace width calculator here returns the minimum width in millimetres and mils. It is deliberately labelled an estimate: the newer IPC-2152 standard, built on far more test data, accounts for board material, thickness and neighbouring copper, and gives kinder answers for many real boards.
Power traces get width generously and early in the layout, before the signal routing crowds them. Vias are part of the path: a string of narrow vias can bottleneck a fat trace, so stitch several in parallel for real current. Keep high-current loops short and wide, because the same resistance that heats also drops voltage, and a ground trace carrying return current can lift a sensitive circuit's reference. When a prototype board comes back, measure: run the load, and a finger or a thermal camera across the power path will tell you within seconds whether the estimate and the board agree. One more limit hides behind the thermal one: voltage drop. A trace wide enough thermally can still drop meaningful voltage at high current, because its resistance is set by length and cross-section together, and a few milliohms in a ground return can offset an analogue reference or make a regulator regulate the wrong point. Power designers therefore check both budgets, temperature and millivolts, and use copper pours and planes where traces run out of width. Kelvin connections, separate sense traces that carry no current, let a regulator or a current monitor measure at the load rather than at its own pins. The width formula answers the heating question; the drop question is Ohm's law, and a finished design has asked both.
The free calculator that goes with this guide:
Open the trace width calculator