The world's mains split along lines drawn in the 1890s. Edison's American system settled near 110 volts DC, then AC; European engineers, free to choose later and eyeing copper costs, doubled the voltage, since higher voltage delivers the same power at half the current and a quarter of the cable loss. Frequency split too: 60 hertz in North America and parts of Asia, 50 hertz in Europe and most of the rest, each camp's choice tangled with the generator designs and lighting flicker of the day. Neither side is simply better; 230 volts is more efficient and more dangerous, 120 volts gentler and hungrier for copper.
About two thirds of the world uses 220 to 240 volts at 50 hertz; the Americas, Japan and a few others use 100 to 127 volts, mostly at 60 hertz, with Japan split between both frequencies down its middle. Plug shapes multiply the confusion into more than a dozen types. The modern rescue is the switch-mode supply: most phone, laptop and camera chargers accept 100 to 240 volts at either frequency and need only a mechanical plug adapter. Heating appliances, hair dryers, motors and anything with a transformer or a clock are the dangerous exceptions, built for one voltage and unforgiving of the other.
The RMS figure on the socket is the start of design work. Its peak, 325 volts on a 230 volt system, sets capacitor and insulation ratings. Its frequency sets transformer size and the ripple calculations in every power supply, and explains why a supply designed for 60 hertz runs warmer on 50. Equipment built for export is tested against the whole map, and the wide-input supply in your laptop is a small monument to a century of incompatible decisions. The RMS converter here moves between the quoted figure and the peak the components actually endure, the translation that datasheet limits are written in. One more number completes the traveller's and the designer's picture: tolerance. Mains voltage is a nominal promise kept within a band, commonly plus or minus 10 percent in modern harmonised systems, so a 230 volt socket may honestly deliver anything from about 207 to 253 volts across the day and the district. Equipment is designed and tested across that band, transformers are tapped with it in mind, and the capacitor on a 230 volt rail is chosen for the top of the band plus surges, not the middle. Brownouts and swells are the band's unruly edges, and the gear that survives decades of them is the gear whose designer treated the socket as a range rather than a constant.